Page 62 - Catalogo Tejas Borja 2016 Ingles x
P. 62
TECHNICAL INFORMATION PLANA ALICANTINA
PLANA ALICANTINA
Size
430 mm x 252 mm
Minimum pitch recommended:
40% - 22o
Weight
3,15 kg/unit
Useful length (batten distance)
370 mm
Useful width
215 mm
Lateral overlap
60 mm
Head overlap
37 mm
Units per sq. m.
12,3 tiles
Weight per sq. m.
39 Kg
Units per ml eave line
5,0 tiles
Roof Tiles per pallet (*)
240 / 140 / 210 / 280 units
Waterproofing
Waterproof membrane
Battens per sq. m.
2,7
Approximate values: If the roof tiles are installed on battens, the useful length must be calculated on site.
A tolerance of ± 2% is allowed on the dimensions of the roof tiles according to UNE - EN 1024.
(*) See more details on www.tejasborja.com
WHY DRY INSTALLATION?
Dry installation has significant advantages over conventional installation, as well as improving the performance of the roof during both
summer and winter.
To ensure that the roof is installed correctly, air must circulate continuously in the space under the roof tiles. This micro-ventilation
will allow air to enter via the eave lines and leave through the ridge lines, increasing through the use of ventilation roof tiles distributed
along the roof.
During the summer this air chamber will reduce the amount of heat received by the support for the roof tile and, therefore, the heat
transferred into the building, reducing air conditioning costs. In winter, indoor ventilation will prevent condensation from forming on
the materials used to build up the roof (roof tiles, insulation, support, etc.), as they harm their durability. Furthermore, this condensa-
tion can affect the comfort of the building, producing moisture that is conducive to the formation of moss and bacteria that reduce
the quality of the air inside.
With regards fittings, the use of mortar is not recommended due to its poor reaction with ceramics and the rigidity of joints. Roof tiles
should be fixed mechanically or with adhesives made specifically for roof tiles, since these give the materials the necessary room to
allow for the movements caused by expansion and changes in temperature.
ROOF SLOPES
Each roof must be planned taking into account where it should be built and the length of the deck, in accordance with the technical
standards applicable in each territory. It is for this reason that for each area and location, must take into account of the minimum
slopes for installation and the roof length.
Pitch panel according to the roof length and the location.
(according to UNE - 136020)
Location
Roof length up to 6.5 m
Roof length from 6.5 to 9 m
Roof length from 9 to 12 m
Protected
35% - 19,5o
40% - 22o
50% - 26,5
Normal
40% - 22o
50% - 26,5o
60% - 31o
Exposed
60% - 31o
70% - 35o
80% - 39o
Use the breathable/waterproof membrane on the support.
A special study should be carried out for roof length more than 12m in length (ask us).
60