FITTINGS INSTRUCTIONS CURVED ROOF TILES
6
7
2
4
1
5
3
RECOMMENDATIONS
To ensure their optimal installation, CellerĀ® 50x21 roof tiles should be installed using the Step CellerĀ® 50x21 as a pan and should
be fixed to a support previously prepared with a double batten layout. Curved roof tiles can also be dry installed on under-tile
Corrugated bitumen sheet or Fiber cement sheets.
* Check website www.tejasborja.com for more fitting guide videos.
1
Double batten layout structure. Battens of at least 3cm Structure with under-tile Corru- )
in height. Primary battens (L1) are installed perpendi- gated bitumen sheet or Fiber (L1
cular to the steepest slope 50-70 cm apart and equa-
cement sheets. Follow Guide
lly spaced out along the length of the roof surface. for installation in force for these (
Secondary battens (L2) are installed distributing the products.
L2)
roof tiles according to their useful length. The useful
length must be calculated on site and depends on
the location and the pitch of the roof (see the Code of
practice for installation of roofs with clay roofing tiles
applicable in each zone of application). The second L2 Waterproof and breathing
depends on the (flight) of the eave line and the useful membrane
length of each tile.
2
For the dry installation of cover roof tiles, special clips should
be used, so that the overlap remains constant on all rows of the
roof surface. On steep slopes, it is also recommended that the
joint also be secured with a spot of special foam for tiles.
Curved roof tile fixing clip
76