FITTING INSTRUCTIONS S-INTERLOCKING ROOF TILES
6
7
2
4
1
3
5
RECOMMENDATIONS
To ensure their optimal installation, S-Interlocking roof tiles should be fixed to a support previously
prepared with a double batten layout.
For more information on the dry installation of S-Interlocking roof tiles, watch the explanatory video at www.tejasborja.com
1
A breathable waterproof membrane should be laid on the su-
L1)
pport of the roof and the main battens (L1) should be installed (
every 50/70 cm, parallel to the steepest slope. The horizontal
support battens (L2) for the roof tiles should be fixed to the main
(L2)
battens depending on the useful length of each roof tile (the
useful length must be calculated on site).
Waterproof and breathing
membrane
2
To adequately solve roof joints and chimneys, multi-use (Pre-
mium or Aluminium) waterproofing bands should be used.
Once attached to the clean dry surface, they must then be
finished with the Counter flashing profile, sealing the upper line
with a continuous line of putty.
Multi-use PREMIUM
See more ROOF COMPONENTS on page 92 or at www.tejasborja.com